Pharmacy MCQ Questions - Set 24.
A. Microscopy.
B. Anderson pipette.
C. Sieving.
D. Cascade Impactor.
B. Anderson pipette.
C. Sieving.
D. Cascade Impactor.
2. In flash point, the product is chilled to.
A. 25 ° F.
B. 25° C.
C. 31 ° C.
D. None.
B. 25° C.
C. 31 ° C.
D. None.
3. Flash point is determined by.
A. Light Microscope.
B. Cone and Cup Apparatus.
C. Tag Open cup apparatus .
B. Cone and Cup Apparatus.
C. Tag Open cup apparatus .
4. Density is determined by.
A. Stalagnometer.
B. Density Bottle.
C. Pycnometer.
D. A and C both.
B. Density Bottle.
C. Pycnometer.
D. A and C both.
5. The flame projection is for how many minutes.
A. 5 minutes.
B. 4 minutes.
C. 0.0667 minutes.
D. None.
B. 4 minutes.
C. 0.0667 minutes.
D. None.
6. Aerosols are available in which form.
A. Solutions.
B. Inhalationals.
C. Suspensions.
D. All.
B. Inhalationals.
C. Suspensions.
D. All.
7. The diameter of Aerosol particle is.
A. 50 micrometer.
B. 50 mm.
C. larger than 10 micrometer.
D. Smaller than 10 micrometer.
B. 50 mm.
C. larger than 10 micrometer.
D. Smaller than 10 micrometer.
8. Hot stage microscopy is used for.
A. Particle size.
B. Particle diameter.
C. Particle volume.
D. Polymorphs.
E. Psuedo polymorphs.
B. Particle diameter.
C. Particle volume.
D. Polymorphs.
E. Psuedo polymorphs.
9. TGA is for.
A. Temperature Analysis.
B. Thermal Analysis.
C. Pressure Analysis.
D. All.
B. Thermal Analysis.
C. Pressure Analysis.
D. All.
10. Diosna mixer is used in.
A. Parentrals.
B. Powders.
C. Capsules.
D. None.
B. Powders.
C. Capsules.
D. None.
11. The most effiecient granulator is used in the manufacturing of tablet.
A. RMG.
B. Chisonator.
C. FBD.
D. A and C both.
B. Chisonator.
C. FBD.
D. A and C both.
12. Osmolarity is the property of.
A. Stability.
B. Solubility.
C. Physical.
D. Bulk Chemical analysis.
B. Solubility.
C. Physical.
D. Bulk Chemical analysis.
13. The disintegration time of Soft gelatin capsules.
A. 60 minutes.
B. 15 minutes.
C. 30 Minutes.
D. None.
B. 15 minutes.
C. 30 Minutes.
D. None.
14. The dissolution time of Hard gelatin capsules.
A. 30 minutes.
B. 60 minutes.
C. 120 minutes.
D. 115 minutes.
B. 60 minutes.
C. 120 minutes.
D. 115 minutes.
15. Disintegration test Apparatus I.P. covers.
B. 35 to 39 cycles.
C. 28 to 32 cycles /min.
D. None.
Answers
1. Cascade Impactor.
2. 31 ° C.
3. Tag Open cup apparatus.
4. Pycnometer.
5. 0.0667 minutes.
6. Suspensions.
7. Smaller than 10 micrometres.
8. Psuedo polymorphs.
9. Thermal Analysis.
10. None.
11. RMG.
12. Physical.
13. None.
2. 31 ° C.
3. Tag Open cup apparatus.
4. Pycnometer.
5. 0.0667 minutes.
6. Suspensions.
7. Smaller than 10 micrometres.
8. Psuedo polymorphs.
9. Thermal Analysis.
10. None.
11. RMG.
12. Physical.
13. None.
14. 30 minutes.
15. None.
15. None.