Thursday 1 February 2018

Pharmacy MCQ Questions and Answers - Set 20

Pharmacy MCQ Questions - Set 20.
1. Size of the sample to be injected in GC with the normal column is.
A. 0.02 microliter.
B. 1 to 10 microliter.
C. 1 to 10 ml.
D. 0.2 microliter.

2. Kovat's retention index is used to characterise?
A. Analyte.
B. Solvent.
C. Liquid stationary phase.
D. Column.

3. Which of the following group is detected by using Herzig Meyer method?
A. Alkyl group.
B. Hydroxy group.
C. Alkoxy group.
D. N-alkyl group.

4. In GC, sample is injected using.
A. Rheodyne injector.
B. Microsyringe.
C. Flow injection.
D. None of these.

5. Metastable peaks are always present at.
A. Even mass numbers.
B. Integral mass numbers.
C. Odd mass.
D. Non-integral mass.

6. In HPLC, which pump gives a mobile phase flow rate dependent on column permeability?
A. Constant pressure pumps.
B. Constant displacement pumps.
C. Reciprocating pumps.
D. Pneumatic pumps.

7. Which one is used as Cuticle Remover?
A. Nitrocellulose.
B. Mineral oil.
C. Trisodium phosphate.
D. Acetoglyceride.

8. Use of infusion of Tulsi leaves?
A. Insecticidal.
B. Spasmolytic.
C. Stomachic.
D. Stimulant.

9. Which of the following is the active metabolite of Quinidine?
A. 3-Hydroxy quinidine.
B. 3-hydroxy quinine.
C. 2-Hydroxy quinidine.
D. 2-hydroxy quinine.

10. One of the following amino acids contains imidazole ring?
A. Proline.
B. Asparagine.
C. Tryptophan.
D. Histidine.

11. Which of the following is not an example for synthetic hair dye?
A. Para- toluene diamine.
B. p-phenylenediamine.
C. Sulpho-ortho-amino phenol.
D. Lead acetate with precipitated sulphur.

12. Which of the following drying method under controlled conditions results in changes in chemical composition?
A. Processing.
B. Mulching.
C. Curing.
D. Fermentation.

13. Polarogram of a solution containing an electro-reducible substance is obtained by plotting?
A. Potential Vs Volume.
B. Current Vs Volume.
C. Resistance Vs Time.
D. Current Vs Potential.

14. Which of the following is the IUPAC name for Progesterone?
A. Pregn-2-ene-3, 20-dione.
B. Pregn-4, 6-dien-3, 20-dione.
C. Pregn-2, 6-diene-3, 20-dione.
D. Pregn-4-ene-3, 20-dione.

15. Which of the following is an example for Thermal Conductivity Detector?
A. Flame Thermocouple Detector.
B. Flame Thermionic Detector.
C. Katharometer.
D. Flame Ionization Detector.
Answers
1. 1 to 10 microliter.
2. Analyte and Liquid stationary phase.
3. N-alkyl group.
4. Microsyringe.
5. Non-integral mass.
6. Constant pressure pumps.
7. Trisodium phosphate.
8. Stomachic.
9. 3-Hydroxy quinidine.
10. Histidine.
11. Lead acetate with precipitated sulphur.
12. Curing.
13. Potential Vs Volume.
14. Pregn-4-ene-3, 20-dione.
15. Katharometer.